1,444 research outputs found
A new method for spatial mode shifting of stabilized optical cavities for the generation of dual-color X-rays
We propose an innovative method to shift the transversal position of the focal point of an optical cavity keeping it actively frequency stabilized. Our cavity is a 4 mirrors bow-tie cavity and the spatial shift of the resonant mode is obtained by properly rotating the two curved mirrors by piezo actuators. This method allows us to move the transversal position of the cavity focal point of 135 ”m in a time of 50 ms, keeping the resonance condition of the cavity by means of the PoundâDreverâHall technique. We propose to use this technique for the generation of 2-color X-rays via Inverse Compton Scattering (ICS). This technique exploits the large average power stored in the high finesse cavity by shifting the laser beam with respect to the electron beam trajectory, hence controlling the spatial superposition of the electron and photon beams in the interaction region. Arranging two cavities assembled one on top of the other, with different collision angle with the electron beam, allows the generation of X-ray bursts of different energies just by swiftly moving the two cavities, switching the two focal points onto the electron beam trajectory, thus activating in sequence two different ICS spectral lines
A Cationic Contrast Agent in X-ray Imaging of Articular Cartilage: Pre-Clinical Evaluation of Diffusion and Attenuation Properties
The aim of this study was the preliminary assessment of a new cationic contrast agent, the CA4+, via the analysis of spatial distribution in cartilage of ex vivo bovine samples, at micrometer and millimeter scale. Osteochondral plugs (n = 18) extracted from bovine stifle joints (n = 2) were immersed in CA4+ solution up to 26 h. Planar images were acquired at different time points, using a microCT apparatus. The CA4+ distribution in cartilage and saturation time were evaluated. Tibial plates from bovine stifle joints (n = 3) were imaged with CT, before and after 24 h-CA4+ bath immersion, at different concentrations. Afterward, potential CA4+ washout from cartilage was investigated. From microCT acquisitions, the CA4+ distribution differentiated into three distinct layers inside the cartilage, reflecting the spatial distribution of proteoglycans. After 24 h of diffusion, the iodine concentration reached in cartilage was approximately seven times that of the CA4+ bath. The resulting saturation time was 1.9 ± 0.9 h and 2.6 ± 2.9 h for femoral and tibial samples, respectively. Analysis of clinical CT acquisitions confirmed overall contrast enhancement of cartilage after 24 h immersion, observed for each CA4+ concentration. Distinct contrast enhancement was reached in different cartilage regions, depending on tissue's local features. Incomplete but remarkable washout of cartilage was observed. CA4+ significantly improved cartilage visualization and its qualitative analysis
Ageing test of the ATLAS RPCs at X5-GIF
An ageing test of three ATLAS production RPC stations is in course at X5-GIF,
the CERN irradiation facility. The chamber efficiencies are monitored using
cosmic rays triggered by a scintillator hodoscope. Higher statistics
measurements are made when the X5 muon beam is available. We report here the
measurements of the efficiency versus operating voltage at different source
intensities, up to a maximum counting rate of about 700Hz/cm^2. We describe the
performance of the chambers during the test up to an overall ageing of 4 ATLAS
equivalent years corresponding to an integrated charge of 0.12C/cm^2, including
a safety factor of 5.Comment: 4 pages. Presented at the VII Workshop on Resistive Plate Chambers
and Related Detectors; Clermont-Ferrand October 20th-22nd, 200
Insights on the association between thyroid diseases and colorectal cancer
Benign and malignant thyroid diseases (TDs) have been associated with the occurrence of extrathyroidal malignancies (EMs), including colorectal cancers (CRCs). Such associations have generated a major interest, as their characterization may provide useful clues regarding diseasesâ etiology and/or progression, with the possible identification of shared congenital and environmental elements. On the other hand, elucidation of the underlying molecular mechanism(s) could lead to an improved and tailored clinical management of these patients and stimulate an increased surveillance of TD patients at higher threat of developing EMs. Here, we will examine the epidemiological, clinical, and molecular findings connecting TD and CRC, with the aim to identify possible molecular mechanism(s) responsible for such diseasesâ relationship
BriXs ultra high fluxinverse compton source based on modified push-pull energy recovery linacs
We present a conceptual design for a compact X-ray Source BriXS (Bright and compact
X-ray Source). BriXS, the first stage of the Marix project, is an Inverse Compton Source (ICS) of
X-ray based on superconducting cavities technology for the electron beam with energy recirculation
and on a laser system in Fabry-PĂ©rot cavity at a repetition rate of 100 MHz, producing 20â180 keV
monochromatic X-Rays devoted mainly to medical applications. An energy recovery scheme based on
a modified folded push-pull CW-SC twin Energy Recovery Linac (ERL) ensemble allows us to sustain
an MW-class beam power with almost one hundred kW active power dissipation/consumption
çŸćčŽäžćœæć§ćŠćèźź
The present paper describes the Level-1 Barrel Muon Trigger performance as expected with the current configuration of the RPC detectors, as designed for the Barrel Muon Spectrometer of ATLAS. Results of a beam test performed at the X5-GIF facility at CERN are presented in order to show the trigger efficiency with different conditions of RPC detection efficiency and several background rates. Small RPC chambers with part of the final trigger electronics are used, while the trigger coincidence logic is applied off-line using a detailed simulation model. copy 2003 Published by Esevier B.V. 3 Refs
System Test of the ATLAS Muon Spectrometer in the H8 Beam at the CERN SPS
An extensive system test of the ATLAS muon spectrometer has been performed in
the H8 beam line at the CERN SPS during the last four years. This spectrometer
will use pressurized Monitored Drift Tube (MDT) chambers and Cathode Strip
Chambers (CSC) for precision tracking, Resistive Plate Chambers (RPCs) for
triggering in the barrel and Thin Gap Chambers (TGCs) for triggering in the
end-cap region. The test set-up emulates one projective tower of the barrel
(six MDT chambers and six RPCs) and one end-cap octant (six MDT chambers, A CSC
and three TGCs). The barrel and end-cap stands have also been equipped with
optical alignment systems, aiming at a relative positioning of the precision
chambers in each tower to 30-40 micrometers. In addition to the performance of
the detectors and the alignment scheme, many other systems aspects of the ATLAS
muon spectrometer have been tested and validated with this setup, such as the
mechanical detector integration and installation, the detector control system,
the data acquisition, high level trigger software and off-line event
reconstruction. Measurements with muon energies ranging from 20 to 300 GeV have
allowed measuring the trigger and tracking performance of this set-up, in a
configuration very similar to the final spectrometer. A special bunched muon
beam with 25 ns bunch spacing, emulating the LHC bunch structure, has been used
to study the timing resolution and bunch identification performance of the
trigger chambers. The ATLAS first-level trigger chain has been operated with
muon trigger signals for the first time
- âŠ